Overview
Qdos H-FLO: chemical metering and dosing pump
Our latest pump to the range, Qdos H-FLO is designed specifically for higher flow rates up to 600 L/hr.
Delivering the same accuracy and reliability as other Qdos metering and dosing pumps. Qdos H-FLO pumps offer long maintenance intervals - reducing the impact of process downtime and lowering the overall cost of ownership.
Eliminate ancillary equipment
A diaphragm metering pump often requires a range of high maintenance ancillary items to function.
Qdos pumps eliminate the need for ancillary equipment while ensuring accurate, linear and repeatable metering across all process conditions.
Chemical compatibility guide
Features and benefits
- Qdos® H-FLO offers flow rates up to 600 L/h (158.5 USGPH) and pressure capability up to 7 bar (102 psi)
- RFID Pumphead detection ensures confirmation of correct pumphead
- Revolution counter for pumphead service maintenance
- One common pump drive with several pumphead options for changing process conditions and chemistries
- Network integration, control and communication options include EtherNet/IP™, PROFIBUS® and PROFINET®
- Optional pressure sensing kit with configurable alarms for process monitoring
Technical summary
| Max. flow rate | 600 L/h |
| Min. flow rate | 0.12 L/h |
| Max. flow rate | 158.5 USGPH |
| Min. flow rate | 0.032 USGPH |
| Max. operating pressure | 7 bar |
| Max. operating pressure | 102 psi |
| Ambient temperature | 41 °F to 113 °F
(5 °C to 45 °C) |
| Control types | EtherNet/IP™, Manual, PROFIBUS®, PROFINET®, Universal, Universal+ |
| Standards | CAN/CSA-C22.2 NO. 61010-1-12 (R2022), CC 47CFR (Part 15), EN 301 489-1 (17), EN 61326-1:2021, EN60204-1:2018, NSF 61, PSE, RoHS, UL 61010-1:2012 Ed.3 |
| Drive power supply | 100 to 240 VAC 50 to 60 Hz 350 VA |
Technical Summary table lists features available within the range. See ‘Technical specifications’ tab for model specific information.
Performance
Performance
| Pumphead |
Flow rate |
Discharge pressure |
Fluid temperature |
|
Min. |
Max. |
Max. |
Max. |
| ReNu 150 Santoprene |
0.12 L/h (0.032 USGPH) |
150 L/h (39.62 USGPH) |
7 Bar (102 PSI) |
45 °C (113 °F) |
| ReNu 300 Santoprene |
0.12 L/h (0.032 USGPH) |
300 L/h (79.36 USGPH) |
5 Bar (73 PSI) |
45 °C (113 °F) |
|
ReNu 300 SEBS |
0.12 L/h (0.032 USGPH) |
300 L/h (79.36 USGPH) |
4 Bar (58 PSI) |
40 °C (104 °F) |
| ReNu 600 Santoprene |
0.12 L/h (0.032 USGPH) |
600 L/h (158.50 USGPH) |
2.5 Bar (36 PSI) |
45 °C (113 °F) |
The above are certified to NSF/ANSI/CAN 61 and to NSF/ANSI/CAN 372 for lead free requirements
Specifications
Technical specifications
| Qdos H-FLO |
| FlowRateRange | 0.12 L/h to 600 L/h |
| FlowRateRange | 0.032 USGPH to 158.5 USGPH |
| Max. operating pressure | 102 psi (7 bar) |
| 0.1 rpm to 190 |
| Ambient temperature | 41 °F to 113 °F
(5 °C to 45 °C) |
| Weight | 33 lbs (15 kg) |
| Control types | EtherNet/IP™, Manual, PROFIBUS®, PROFINET®, Universal, Universal+ |
| Standards | CAN/CSA-C22.2 NO. 61010-1-12 (R2022), CC 47CFR (Part 15), EN 301 489-1 (17), EN 61326-1:2021, EN60204-1:2018, NSF 61, PSE, RoHS, UL 61010-1:2012 Ed.3 |
| Max. altitude | 6562 ft (2000 m) |
| Drive power supply | 100 to 240 VAC 50 to 60 Hz 350 VA |
Minimum and maximum flow depends upon pumphead, flow unit and method of control. Pressure and speed depends on pumphead chosen. Weight is of drive and pumphead combined.
Dimensions
| A |
B |
C |
D |
E |
F |
| mm |
in |
mm |
in |
mm |
in |
mm |
in |
mm |
in |
mm |
in |
| 276.0 |
10.866 |
35.0 |
1.378 |
224.0 |
8.819 |
260.0 |
10.236 |
33.7 |
1.327 |
291.5 |
11.476 |
| G |
H |
I |
J |
K |
L |
| mm |
in |
mm |
in |
mm |
in |
mm |
in |
mm |
in |
mm |
in |
| 380.0 |
14.961 |
118.7 |
4.673 |
334.3 |
13.161 |
394.2 |
15.520 |
332.3 |
13.083 |
482.0 |
18.976 |
| Qdos pump with gland connections shown. For other configurations see product reference manual. |
Materials of construction
| Fluid connectors | PVC |
| Lubricant | PFPE based |
| Pumphead body assembly | 20 % glass filled PPE/PS, 20% glass filled PPE/PS |
| Tubing | Santoprene, SEBS |
| Fluid connection port | Glass filled polypropylene, PVDF |
| Fluid connection seals | FKM |
| Information labels | Polyester, Polyester resin (PET) |
| Connection collar | PVC |
| Keypad/HMI cover | Polycarbonate (PC) |
| Driveshaft seal | Santoprene |
| Baseplate | 20% glass filled PPE/PS |
Control
Control options
| Input/Output control connection options - Universal and Universal+ models only |
| |
M: M12 connectors |
T: User-wired cable gland connectors |
| Input |
Analogue: 4-20 mA, Digital: 24V IEC61131-2 Type 3 |
Analogue: 4-20 mA, Digital: 24V IEC61131-2 Type 3, AC: 110VAC |
| Output |
Analogue: 4-20 mA, Digital: Relay-CO 1A 24VDC |
Analogue: 4-20 mA, Digital: Relay-CO 5A 110VAC, 5A 30VDC |
| Input control connection for Manual pump |
| Input (Run stop only) |
Digital:24V IEC61131-2 Type 3 |
N/A |
| |
| Operational modes |
Manual |
Universal |
Universal+ |
EtherNet/IP |
PROFIBUS |
PROFINET |
| Manual |
● |
● |
● |
● |
● |
● |
| Bus Network Communication |
|
|
|
● |
● |
● |
| Contact mode |
|
● |
● |
|
|
|
| 4-20 mA |
|
● |
● |
|
|
|
| Fault reporting |
● |
● |
● |
● |
● |
● |
| |
| Features |
Manual |
Universal |
Universal+ |
EtherNet/IP |
PROFIBUS |
PROFINET |
| RFID pumphead detection |
● |
● |
● |
● |
● |
● |
| Numerical flow display |
● |
● |
● |
● |
● |
● |
| Numerical speed display |
● |
● |
● |
● |
● |
● |
| Fluid level monitor |
● |
● |
● |
● |
● |
● |
| Max (prime) |
● |
● |
● |
● |
● |
● |
| Auto restart (after power restored) |
● |
● |
● |
● |
● |
● |
| Fluid recovery |
● |
● |
● |
● |
● |
● |
| Leak detection |
● |
● |
● |
● |
● |
● |
| 5” (127 mm) colour TFT display |
● |
● |
● |
● |
● |
● |
| Pressure sensing (optional pressure sensor) |
|
● |
● |
● |
● |
● |
| |
| Control methods |
Manual |
Universal |
Universal+ |
EtherNet/IP |
PROFIBUS |
PROFINET |
| Input/Output options |
M |
M or T |
M or T |
M |
M |
M |
| Manual control capability |
● |
● |
● |
● |
● |
● |
| 4-20 mA input & calibration |
|
● |
● |
|
|
|
| 4-20 mA output |
|
|
● |
|
|
|
| Contact input (pulse/batch) |
|
● |
● |
|
|
|
| Pressure sensor input (pressure sensor purchased separately) |
|
● |
● |
● |
● |
● |
| Manual speed adjustment range* |
1900:1 |
1900:1 |
1900:1 |
1900:1 |
1900:1 |
1900:1 |
| Minimum drive shaft adjustment speed increment |
0.1 |
0.1 |
0.1 |
0.1 |
0.1 |
0.1 |
| 4-20 mA resolution |
|
2184:1 |
2184:1 |
|
|
|
| Run stop input |
● |
● |
● |
|
|
|
| Run status output |
|
● |
● |
|
|
|
| Alarm output |
|
● |
● |
|
|
|
| Four configurable relay outputs |
|
● |
● |
|
|
|
| Remote fluid recovery input |
|
● |
● |
● |
● |
● |
| *Speed adjustment range depends upon pumphead chosen, maximum shown |
| |
| EtherNet/IP, PROFIBUS and PROFINET functions |
Manual |
Universal |
Universal+ |
EtherNet/IP |
PROFIBUS |
PROFINET |
| Speed set point |
|
|
|
● |
● |
● |
| Speed feedback |
|
|
|
● |
● |
● |
| Flow calibration function |
|
|
|
● |
● |
● |
| Hours run |
|
|
|
● |
● |
● |
| Revolution counter |
|
|
|
● |
● |
● |
| Leak detection |
|
|
|
● |
● |
● |
| Low fluid level alarm |
|
|
|
● |
● |
● |
| Diagnostic feedback |
|
|
|
● |
● |
● |
| Pressure sensing (optional pressure sensor) |
|
|
|
● |
● |
● |
| |
| Security |
Manual |
Universal |
Universal+ |
EtherNet/IP |
PROFIBUS |
PROFINET |
| Keypad lock |
● |
● |
● |
● |
● |
● |
| PIN lock to protect set up |
● |
● |
● |
● |
● |
● |
| |
Documentation
Pumpheads
Reduced maintenance with single, no-tools, component replacement
Revolutionary ReNu pumphead technology is at the core of the Qdos H-FLO pump. This ensures the delivery of accurate and repeatable flow for fluids of wide ranging viscosities.
ReNu pumpheads provide accurate, linear and repeatable low pulse flow under varying process conditions.
Safe, no tools maintenance. The ReNu pumphead has an integral leak detector which eliminates operator exposure to chemicals.
Qdos H-FLO pumps can be ordered with the ReNu pumphead mounted on the left or right of the pump.
| Pumphead |
Tube material |
Max operating pressure |
Part number |
| ReNu 150 |
Santoprene
A general purpose pumphead with a high chemical compatibility across a range of applications
|
7 bar |
0M3.6200.PFP |
| ReNu 300 |
Santoprene
A general purpose pumphead with a high chemical compatibility across a range of applications
|
5 bar |
0M3.7200.PFP |
|
SEBS
Optimised for sodium hypochlorite, sulfuric acid and hydrogen peroxide applications with discharge pressure up to 4 bar. Please see the chemical compatibility section for further information on suitability with other specific chemicals
|
4 bar |
0M3.7800.PFP |
| ReNu 600 |
Santoprene
A general purpose pumphead with a high chemical compatibility across a range of applications
|
2.5 bar |
0M3.8200.PFP |
Chemical metering systems
Our chemical metering systems are designed to save time and money by providing a complete solution. Offering unparalleled performance, simple maintenance and customer support, each system is designed to perform in the toughest applications and environments.
By combining the pumps, gauges, columns and other system accessories into a complete system, we provide a robust metering solution from a single source.
Learn more
Videos
Order Information
Product codes
Drive product codes
| A |
B |
C |
D |
| Model |
Input/Output connectors |
Pumphead orientation |
Power plug |
3: Manual 4: Universal 5: Universal+ 7: PROFIBUS 8: EtherNet/IP 9: PROFINET
|
M: M12 connectors T: User-wired cable gland connectors |
L: Left R: Right |
A: US
B: Brazil
C: Swiss
D: India, South Africa
E: European
K: Australia
R: Argentina
U: UK
|
Pumphead product codes
| Description |
Product code |
| ReNu 150 pumphead Santoprene |
0M3.6200.PFP |
| ReNu 300 pumphead Santoprene |
0M3.7200.PFP |
| ReNu 300 pumphead SEBS |
0M3.7800.PFP |
| ReNu 600 pumphead Santoprene |
0M3.8200.PFP |