Tubing - peristaltic

GORE STA-PURE PFL tubing

Overview

GORE STA-PURE PFL PTFE reinforced fluroelastomer tubing

STA-PURE PFL handles nearly all aggressive chemicals, including organic solvents such as methyl ethyl ketone, toluene and acetone.

STA-PURE PFL is a high-performance composite of expanded polytetrafluoroethylene (ePTFE) and a platinum-cured perfluoroelastomer, giving extraordinary chemical resistance, extremely long life and very high burst pressures. It is free from plasticisers, acid acceptors and other processing aids, making it one of the purest tubings available.

Leachability tests using ethyl acetate yielded over 100 times less total extractables than other fluoroelastomer tubing materials. In addition, STA-PURE PFL has Class VI tests for pharmaceutical applications.

Chemical Compatibility Guide

 

Features and benefits

  • Highly resistant to aggressive chemicals, including organic solvents
  • 50 times longer life than other fluoroelastomers
  • Stable flow rate over time
  • Pressures up to 60 psi
  • Suitable for CIP/SIP
  • Operating temperature -4 °F to 176 °F
  • Available in 20 different bore sizes, three wall thicknesses and three element lengths
  • STA-PURE PFL are trademarks of WL Gore & Associates Inc.

Technical summary

SpallationVery low 
CertificationUSP Class VI 
Gamma stability25-50kGy 

Technical Summary table lists features available within the range. See ‘Technical specifications’ tab for model specific information.

Specifications

Technical specifications

GORE STA-PURE PFLSTA-PURE PFL elements
Bore size1.6 - 17 mm1.6 - 12 mm
Bore size0.0625 - 0.671875 in0.0625 - 0.46875 in
Wall thickness1.6 - 4.8 mm2.4 - 4 mm
Wall thickness0.0625 - 0.1875 in0.09375 in
Length305 - 610 mm
ColorOff-white Off-white 
TransparencyOpaque Opaque 
SpallationVery low Very low 
CertificationUSP Class VI 
Operating temperature range -20 to 80 °C-20 to 80 °C
Operating temperature range -4 to 176 °F-4 to 176 °F
Hardness, shore A (5sec)85+/-10 85+/-10 
UV resistance Excellent Excellent 
Water absorptionLow Low 
Gamma stability25-50kGy 
Sterilisation methodsAutoclave, CIP, SIP Autoclave, CIP, SIP 
Weight0.1 - 0.24 kg0.1 - 0.2 kg

ASTM methods Hardness: ASTM D 2240; Specific gravity: ASTM D 792; Tear B, Ultimate tensile strength, Elongation at break, Tensile stress at 100 % elongation; ASTM D 412

Materials of construction

TubingePTFE and fluoroelastomer composite

Validation

Validation pack for GORE STA-PURE PFL tubing

Request a validation pack for GORE STA-PURE PFL tubing.

Request full validation guide

Disclaimer: You hereby agree the provided validation guide is for private use only to assist in the qualification of the products listed within the validation guide.

You also agree that you will not copy, redistribute, transmit, assign, sell, broadcast, rent, share, lend, modify, adapt, edit or transfer the validation guide to any other party without prior consent from WMFTG.

Literature

Brochures

  1. Tubing overview (EN).pdf
    PDF - 841.6kb
  2. Biopharm tubing (US).pdf
    PDF - 2.4mb

Datasheet

  1. STApure PFL datasheet (EN).pdf
    PDF - 220.2kb

Order Information

Product codes

GORE STA-PURE PFL product codes

STA-PURE PFL pump tubing sizes available
Bore Wall No Element length Part number
mm inch mm inch   mm
1.6 1/16 1.6 1/16 14 305 966.0016.016
3.2 1/8 1.6 1/16 16 305 966.0032.016
4.8 3/16 1.6 1/16 25 305 966.0048.016
6.4 1/4 1.6 1/16 17 305 966.0064.016
8.0 5/16 1.6 1/16 18 305 966.0080.016
1.6 1/16 1.6 1/16 14 355 966.0016.L16
3.2 1/8 1.6 1/16 16 355 966.0032.L16
4.8 3/16 1.6 1/16 25 355 966.0048.L16
6.4 1/4 1.6 1/16 17 355 966.0064.L16
8.0 5/16 1.6 1/16 18 355 966.0080.L16
1.6 1/16 2.4 3/32 119 355 966.0016.024
3.2 1/8 2.4 3/32 120 355 966.0032.024
4.8 3/16 2.4 3/32 15 355 966.0048.024
6.4 1/4 2.4 3/32 24 355 966.0064.024
8.0 5/16 2.4 3/32 121 355 966.0080.024
9.6 3/8 2.4 3/32 122 610 966.0096.024
6.4 1/4 3.2 1/8 26 610 966.0064.032
9.6 3/8 3.2 1/8 73 610 966.0096.032
12.7 1/2 3.2 1/8 82 610 966.0127.032
15.9 5/8 3.2 1/8 184 610 966.0159.032

Recommended Products

  1. 530 process pumps

    530 process pumps

    Flow rates to 55 GPH (3.5 L/min) and pressures up to 100 psi. Precise 2200:1 speed control range.

    Pumps - cased pumps

  2. 630 mid-flow process pumps

    630 mid-flow process pumps

    Flow rates to 4.76 GPM (18 L/min) and pressures up to 60 psi. Precise 2650:1 speed control range.

    Pumps - cased pumps

  3. 730 process pumps

    730 process pumps

    Flow rates to 8.8 GPM (33 L/min) and pressures up to 30 psi. Precise 3600:1 speed control range.

    Pumps - cased pumps

Related Products

  1. Bioprene: Thermoplastic tubing

    Bioprene: Thermoplastic tubing

    Thermoplastic tubing with long peristaltic life and low permeability. 23 ºF to 176 ºF (5 ºC to 80 ºC).

    Tubing - peristaltic

  2. GORE® STA-PURE Series PCS tubing

    GORE® STA-PURE Series PCS tubing

    Reinforced silicone tubing ideal for biopharmaceutical applications. -4 ºF to 176 ºF (-20 ºC to 80 ºC) to 100 psi.

    Tubing - peristaltic

  3. LoadSure elements

    LoadSure elements

    LoadSure elements allow pump tubing to be changed in under one minute, to achieve perfect tube alignment and tension.

    Tubing - peristaltic

  4. Marprene tubing

    Marprene tubing

    Thermoplastic elastomer tubing especially resistant to oxidizing agents. 23 ºF to 176 ºF (5 ºC to 80 ºC) to 100 psi.

    Tubing - peristaltic

  5. Pumpsil tubing

    Pumpsil tubing

    Platinum-cured silicone tubing with ultra smooth bore and excellent flow stability. -4 ºF to 176 ºF (-20 ºC to 80 ºC).

    Tubing - peristaltic

  6. PureWeld XL tubing

    PureWeld XL tubing

    High performance TPE tubing with exceptional life and accurate flow rates. Weldable and sealable for sterile connectivity.

    Tubing - peristaltic

  7. Tubing for panel mount pumps

    Tubing for panel mount pumps

    High quality silicone and chemical resistant TPE tubing. Over 50 bore/wall sizes and element lengths available.

    Tubing - peristaltic

Our tubing specialists are here to help you succeed.

To order a product or ask a question

Contact our experts