Pumps - panel mount pumps

300 series panel mount pumps

Overview

300 series medium-flow pumps

The 300 series combines performance, practicality and design. With its iconic flip-top design it is an industry standard OEM product in medical device, biotechnology and diagnostic applications, and very popular in many other applications too.

Pumpheads

  • Available in three, four, six and eight roller versions. More rollers for greater accuracy and reduced pulsation. The three-roller 313 pumphead offers maximum flows
  • Great flexibility with 13 tubing sizes providing flows to 2 L/min continuously or 3 L/min intermittently. Strong IXEF moulded pumpheads available in a range of colours
  • Multi-channel versions with 'extension heads' available, depending on drive torque
  • Error-free tube change in seconds

Drives

  • 300DriveSure: 12 V to 48 V DC integrated stepper motor with Industrial Ethernet and analogue control options, sealed mounting plate and PC software (WM Connect)
  • 300VDL/VBM: 24 V brushless DC drive pumps with a maximum speed of 350 rpm and flow rates up to 1,750 mL/min
  • 300FAM: heavy-duty induction drive pumps in two voltage ranges and four maximum speeds and flow rates up to 1,450 mL/min
  • 300FDM: 12 V or 24 V induction drive pumps in four maximum speeds and flow rates up to 1,750 mL/min

Technical summary

Motor typesDriveSure brushless DC motor, Fixed speed DC motor, NEMA 24 stepper motor, Synchronous AC motor, Variable speed brushless DC motor 
Pumphead options313D, 313D2, 314D, 314D2 
StandardsBS EN 55011-2016+A2-2021, BS EN 61010-1, BS EN IEC 61326-1-2021, CAN/CSA C22.2 No 61010-1, CE, CSA C22.2 No. 61010-1-12/AMD1:2018, EN 61010-1:2010/A1:2019, FCC 47CFR (Part 15), IEC 61010-1, IEC 61010-1:2010/AMD1:2016, RoHS, UL 61010-1, UL 61010-1:2012/R:2 

Technical Summary table lists features available within the range. See ‘Specifications’ tab for model specific information.

Performance

300DriveSure/D performance

Flow rates (ml/min) Tubing 1.6 mm wall
Tube bore (mm) 313D pumphead 314D pumphead
Speed (rpm)
8 408 8 408
0.5 0.24 12 0.24 12
0.8 0.56 29 0.48 24
1.6 2.20 112 2.00 102
3.2 8 408 6.80 350
4.8 18 900 15 780
6.4 29 1500 24 1224
8.0 75 2040 32 1632

Flow rates are for guidance only at 0 bar. Always test pumphead flow capability in the relevant fluid system

Flow rates (ml/min) Tubing 2.4 mm wall
Tube bore (mm) 313D pumphead 314D pumphead
Speed (rpm)
8 408 8 408
0.5 0.24 12 0.24 12
0.8 0.56 29 0.48 24
1.6 2.20 112 2.00 102
3.2 8 408 6.80 350
4.8 18 900 15 780
6.4 29 1500 24 1224

Flow rates are for guidance only at 0 bar. Always test pumphead flow capability in the relevant fluid system

300 DriveSure ADC/En/Pn performance

Flow Rate (mL/min) by tube bore based on 0.1 rpm (Min) to 410 rpm (Max)
Pumphead 0.5 mm 0.8 mm 1.6 mm 3.2 mm 4.8 mm 6.4 mm 8.0 mm
Min Max Min Max Min Max Min Max Min Max Min Max Min Max
313D 0.003 12.2 0.007 29.1 0.027 112.5 0.100 410 0.221 904 0.368 1507 0.500 2050
314D 0.003 12.1 0.006 24.1 0.025 102.5 0.086 352 0.191 784 0.300 1230 0.400 1640
313D2 0.003 12.1 0.007 29.1 0.027 112.5 0.100 410 0.221 904 0.368 1507
314D2 0.003 12.1 0.006 24.1 0.025 102.5 0.086 352 0.191 784 0.300 1230

Performance data is based on a 48 V DC power supply, pumping water, with 0 bar inlet and discharge pressure. Actual performance is dependent on power supply voltage (DriveSure range 12 V to 48 V DC). For further information contact your local Watson-Marlow representative.

300 VDL/D performance

313/314 VDL pumps — Flow rates (ml/min)
Tube bore (mm) VDL 24VDC
Speed (rpm)
100 350
0.5 3.00 10.5
0.8 6.00 21.0
1.6 26.0 91.0
3.2 100 350
4.8 220 770
6.4 360 1260
8.0 500 1760

314 flowrates are approximately 85 % of 313 flow rates

Marprene tubing 1.6 mm wall, zero pressure and no suction lift

Nominal flow rates may vary +/-10 %

300 VBM/D performance

313/314 VBM pumps — Flow rates (ml/min)
Tube bore (mm) VBM 24VDC
Speed (rpm)
100 190 360
0.5 3.4 6.5 12
0.8 7.0 14 26
1.6 27 52 100
3.2 100 190 360
4.8 420 790
6.4 360 685 1296
8.0 500 950 1800

314 flowrates are approximately 85 % of 313 flow rates

Marprene tubing 1.6 mm wall, zero pressure and no suction lift

Nominal flow rates may vary +/-10 %

300 FAM/D performance

313/314 FAM pumps — Flow rates (ml/min)
Tube bore (mm) FAM 50Hz FAM 60Hz
Speed (rpm)
37 75 145 290 42 85 170
0.5 1.3 2.6 5.0 10 1.4 3.0 6.0
0.8 2.6 5.4 10 21 3.0 6.0 12
1.6 10 20 39 79 11 23 46
3.2 37 75 145 290 42 85 170
4.8 80 165 320 640 90 190 375
6.4 130 270 520 1045 150 305 610
8.0 185 375 725 1450 210 425 850

314 flowrates are approximately 85 % of 313 flow rates

Marprene tubing 1.6 mm wall, zero pressure and no suction lift

Nominal flow rates may vary +/-10 %

300 FDM/D performance

313/314 FDM pumps — Flow rates (ml/min)
Tube bore (mm) FDM 12/24VDC
Speed (rpm)
45 90 175 350
0.5 1.5 3.0 6.0 12
0.8 3.2 6.4 13 25
1.6 12 24 48 95
3.2 45 90 175 350
4.8 100 198 385 770
6.4 160 325 630 1260
8.0 225 450 875 1750

314 flowrates are approximately 85 % of 313 flow rates

Marprene tubing 1.6 mm wall, zero pressure and no suction lift

Nominal flow rates may vary +/-10 %

Specifications

Technical specifications

300 DriveSure ADC/En/Pn300 VDL/D300 VBM/D300 FAM/D300 FDM/D
Motor typesNEMA 24 stepper motor Variable speed brushless DC motor Variable speed brushless DC motor Synchronous AC motor Fixed speed DC motor 
Pumphead options313D, 313D2, 314D, 314D2 313D, 314D 313D, 314D 313D, 314D 313D, 314D 
Pumphead number of rollers3, 4 3, 4 3, 4 3, 4 
Pumphead number of channels
Min. flow rate 0.003 ml/min3 ml/min0.3 ml/min1.3 ml/min1.35 ml/min
Max. flow rate2050 ml/min1760 ml/min1800 ml/min1450 ml/min1800 ml/min
Min. operating speed0.1 rpm4 rpm4 rpm
Max. operating speed410 rpm350 rpm480 rpm290 rpm360 rpm
Speed Resolution0.1 rpm
Supply voltage12 V to 48 V DC 24 V DC 24 V DC 110 V to 115 V AC, 60 Hz, 220 V to 230 V AC, 50 Hz 12 V DC, 24 V DC 
Operating temperature range 5 °C to 40 °C-10 °C to 40 °C-10 °C to 40 °C-10 °C to 40 °C
Operating temperature range 41 °F to 104 °F23 °F to 104 °F23 °F to 104 °F23 °F to 104 °F23 °F to 104 °F
Rated Power75 W 35 W 60 W 40 W 30 W 
Control options0–10 V, 2–2000 Hz, 4–20 mA, EtherNet/IP™, Fixed speed, Prime speed, PROFINET® 0–4 V 0–4 V Fixed speed, Manual variable speed Fixed speed, Manual variable speed 
AlarmsCover-open, Hardware fault, Over current, Over temperature, Software fault, Speed, Stall, Under/over voltage Cover-Open Cover-Open Cover-Open Cover-Open 
OutputsFault, Tacho Tacho Tacho 
External InputsPrime switch 
Weight1.7 - 2.4 kg1 kg
Weight3.748 - 5.291 lbs
LocationIndoor, Enclosure 
Ingress ProtectionIP66 capable panel sealing IP41, IP41 drive IP41, IP41 drive IP41, IP41 drive 
Humidity80 % up to 31 °C (88 °F), decreasing linearly to 50 % at 40 °C (104 °F) 
Noise<60 dB(A) 
Max. altitude2000 m
Max. altitude6561 ft
Gearbox ratioSpur; 10:1, Spur; 100:1, Spur; 15:1, Spur; 37.5:1 Spur; 10:1, Spur; 20:1, Spur; 40:1, Spur; 5:1, Spur; 7.5:1 Spur; 10:1, Spur; 20:1, Spur; 40:1, Spur; 5:1 Spur; 10:1, Spur; 20:1, Spur; 40:1, Spur; 5:1 
StandardsBS EN 55011-2016+A2-2021, BS EN IEC 61326-1-2021, CSA C22.2 No. 61010-1-12/AMD1:2018, EN 61010-1:2010/A1:2019, FCC 47CFR (Part 15), IEC 61010-1:2010/AMD1:2016, UL 61010-1:2012/R:2019-07 
Certification and complianceCB Certificate, EMC, NRTL certification 
Compatible tubing bore size 0.5, 0.8, 1.6, 3.2, 4.8, 6.4, 8 mm0.5, 0.8, 1.6, 3.2, 4.8, 6.4, 8 mm0.5, 0.8, 1.6, 3.2, 4.8, 6.4, 8 mm0.5, 0.8, 1.6, 3.2, 4.8, 6.4, 8 mm0.5, 0.8, 1.6, 3.2, 4.8, 6.4, 8 mm
Compatible tubing wall thickness 1.6, 2.4 mm1.6 mm1.6 mm1.6 mm1.6, 2.4 mm
Outputs are for ADC version only. Alarms are for EtherNet/IP™ & PROFINET® versions only. For detailed specifications of individual models refer to product reference manual or contact WMFTS representative.

300 DriveSure ADC/En/Pn dimensions

Motor A B C D E F
mm in mm in mm in mm in mm in mm in
Standard NEMA 24 stepper motor (most applications) 101 3.98 93 3.68 128 5.04 160 6.30 92 3.62 103 4.06
High torque NEMA 24 stepper motor (demanding applications) 190 7.48 123 4.82

The 300 series has two drive options comprising a standard motor which covers most applications and a longer motor for applications requiring higher torque. Motor choice considerations include tube size, material, speed and pressure.

Specify motor type in product code or contact your local Watson-Marlow representative

300 VDL/D dimensions

300 VBM/D dimensions

300 FAM/D dimensions

300 FDM/D dimensions

Materials of construction

Pumphead body assemblyGlass filled polypropylene, Polyacrylamide—IXEF (PARA), Stainless steel
Pumphead rotor assemblyElectroless nickel plated hardened steel, Glass filled Nylon
Pumphead roller assemblyMoS2 filled Nylon 6 (Nylatron)
MotorAluminium, Plasma nitride coated stainless steel
Controller HousingABS/PC, Aluminium
Mounting plate assemblyNitrile, Polyacrylamide (PARA)-halogen free, UL94 V-0 rated, Thermoplastic elastomer (TPE)

Information listed covers the complete range. For detailed specifications of individual models/components refer to product reference manual or contact WMFTS representative.

Literature

Datasheet

  1. Original DriveSure datasheet (EN).pdf
    PDF - 375.3kb
  2. 300 DriveSure ADCEnPn datasheet (EN).pdf
    PDF - 995kb
  3. 313FDP datasheet (EN).pdf
    PDF - 108.8kb
  4. 313FAM FDM VBM datasheet (EN).pdf
    PDF - 206.4kb
  5. 313VDL datasheet (EN).pdf
    PDF - 131.5kb

Manuals

  1. DriveSure ADC En Pn manual (EN).pdf
    PDF - 4.7mb

Other Resources

  1. 300 DriveSure ADC.stp
    STP - 19.5mb
  2. 300 DriveSure En.stp
    STP - 20.1mb
  3. 300 panel cutout.stp
    STP - 43.2kb
  4. 300 DriveSure Pn.stp
    STP - 20.1mb
  1. GSDML-V2.42-Watson Marlow-WM DrivesurePn-20230427.zip
    ZIP - 3.9kb
  2. WatsonMarlowConnectInstaller-1.16.1.zip
    ZIP - 67mb
  3. WatsonMarlowConnectInstaller-1.17.0.zip
    ZIP - 67mb
  1. drivesure-firmware-1.17.0.bundle
    BUNDLE - 598.2kb
  2. drivesure-firmware-1.16.1.bundle
    BUNDLE - 596.8kb
  1. WM-DrivesureEn-v1-6.eds
    EDS - 84.4kb
  2. WM-DrivesureEn-rev-1-5.eds
    EDS - 84.7kb

Videos

Order Information

Product codes

300DriveSure/D product codes

Pump product codes
Description Motor control Product code
PMD24CV300 0 - 10 V Contact your local Watson-Marlow representative
PMD24CI300 4 - 20 mA Contact your local Watson-Marlow representative
PMD48CV300 0 - 10 V Contact your local Watson-Marlow representative
PMD48CI300 4 - 20 mA Contact your local Watson-Marlow representative

For mounting plate options, test leads and further pumphead configurations, contact your local Watson-Marlow sales representative

300 VDL/D product codes

Pump product codes
Description Supply voltage Speed (rpm) Number of channels Product code
313VDL/D 24 VDC 100 040.NP10.3D0
24 VDC 350 040.NU10.3D0

Silicone 8.0 mm no backpressure

Marprene max 6.4 mm no backpressure

300 VBM/D product codes

Pump product codes
Description Supply voltage Speed (rpm) Number of channels Product code
313VBM/D 24 VDC 100 3 040.NP23.010
24 VDC 190 2 040.NS23.010
24 VDC 360 1 040.NV23.010

Silicone 8.0 mm no backpressure

Marprene max 6.4 mm no backpressure

300 FAM/D product codes

Pump product codes
Description Supply voltage Speed (rpm) Number of channels Product code
313FAM/D 230 VAC, 50 Hz 37 6 040.AG23.010
115 VAC, 60 Hz 42 4 040.EH23.010
230 VAC, 50 Hz 75 4 040.AN23.010
115 VAC, 60 Hz 85 2 040.EP23.010
230 VAC, 50 Hz 145 2 040.AQ23.010
115 VAC, 60 Hz 170 1 040.ER23.010
230 VAC, 50 Hz 290 1 040.AU23.010

Silicone 8.0 mm no backpressure

Marprene max 6.4 mm no backpressure

300 FDM/D product codes

Pump product codes
Description Supply voltage Speed (rpm) Number of channels Product code
313FDM/D 12 VDC 45 6 040.CH23.010
24 VDC 45 6 040.DH23.010
12 VDC 90 4 040.CP23.010
24 VDC 90 4 040.DP23.010
12 VDC 175 2 040.CR23.010
24 VDC 175 2 040.DR23.010
12 VDC 350 1 040.CV23.010
24 VDC 350 1 040.DV23.010

Silicone 8.0 mm no backpressure

Marprene max 6.4 mm no backpressure

300 DriveSure ADC/En/Pn product codes

A
B
C
D
E
F
G
H
Product
Control
Cable length
Pumphead colour
Motor Type
Pumphead
Tube clamp
Tube wall thickness
0 = Complete pump 4 = ADC 1 = 1 m (3.28 ft) cable 0 = No pumphead A = Standard NEMA 24 stepper motor 0 = No pumphead 0 = No pumphead 0 = No pumphead
6 = Drive only 8 = En (EtherNet/IPTM) 3 = 3 m (9.84 ft) cable 1 = Standard colour C = High torque NEMA 24 stepper motor C = 313D/313D2 V = Variable 1 = 1.6 mm
9 = Pn (PROFINET®) 2 = Black D = 314D/314D2 C = Fixed 0.5 mm to 1.6 mm bore 2 = 2.4 mm
3 = White F = Fixed 3.2 mm bore
K = Fixed 4.8 mm bore
N = Fixed 6.4 mm to 8.0 mm bore
Accessories and Spares
Product Product code
300 Series DriveSure Sealed Mounting Plate / Sensor 039.IPMP.DVS
DriveSure cable pack - 24 V power supply/USB-C - trials only * 009.24CP.DVS
DriveSure cable pack - 48 V power supply/USB-C - trials only * 009.48CP.DVS
1 m Power Cable DriveSure ADC/En/Pn 009.1PW.DVS
3 m Power Cable DriveSure ADC/En/Pn 009.3PW.DVS
1 m Control Cable DriveSure ADC 009.1CC.DVS
3 m Control Cable DriveSure ADC 009.3CC.DVS
Ethernet Cable, RJ45 to RJ45, CAT 5e SHIELDED, 3m 059.9123.000
PROFINET® Cable, RJ45 to RJ45, CAT 5e SHIELDED, 3m 059.9128.000

*Cable packs do not include mains power lead. If required, order power leads suitable for your region.

Recommended Products

  1. 300 series pumpheads

    300 series pumpheads

    Iconic flip-top pumps for medium flows to 2,000 ml/min. Extendable up to 6 channels.

    Pumpheads

  2. 300MC pumpheads

    300MC pumpheads

    High accuracy microcassettes for manifold tubing for flow rates up to 53 ml/min.

    Pumpheads

  3. Bioprene: Thermoplastic tubing

    Bioprene: Thermoplastic tubing

    Thermoplastic tubing with long peristaltic life and low permeability. 5 ºC to 80 ºC (23 ºF to 176 ºF).

    Tubing - peristaltic

  4. Pumpsil tubing

    Pumpsil tubing

    Platinum-cured silicone tubing with ultra smooth bore and excellent flow stability. -20 ºC to 80 ºC (-4 ºF to 176 ºF).

    Tubing - peristaltic

Related Products

  1. 100 series low-flow pumps

    100 series low-flow pumps

    Iconic flip-top pumps for flows up to 500 ml/min. Accurate flow performance to medium pressures.

    Pumps - panel mount pumps

  2. 400/M series compact pumps

    400/M series compact pumps

    One to eight channel pumps for medium flows to 200 ml/min. Compact design and Luer connectors for 'fit and forget' applications.

    Pumps - panel mount pumps

  3. 100 series low-flow pumps

    100 series low-flow pumps

    Iconic flip-top pumps for flows up to 500 ml/min. Accurate flow performance to medium pressures.

    Pumps - panel mount pumps

  4. 400/M series compact pumps

    400/M series compact pumps

    One to eight channel pumps for medium flows to 200 ml/min. Compact design and Luer connectors for 'fit and forget' applications.

    Pumps - panel mount pumps

Our pump specialists are here to help you succeed.

To order a product or ask a question

Contact our experts