Valves - diaphragms

Viton diaphragms

Overview

Viton® diaphragms

Viton® is a class of fluoropolymer elastomer (synthetic rubber) and is well known for its excellent heat, acid and chemical resistance. The performance of fluoroelastomers in aggressive chemicals depends on the grade of the elastomer.

There are three grades of Viton we currently use for our viton diaphragms:

  • Viton A the most commonly used version of Viton, but should not be used with most ketones, esters or extended steam exposure.
  • Viton A (SR) Steam resistant version of Viton A, performs well in conditions with extended steam
  • Viton GF is more chemically resistant than Viton A and offers good steam resistance. However, it should not be used with most ketones and esters.

Features and benefits

Technical summary

Diaphragm variant(s)Bellows, Straight 
Compatible actuatorsAJS, AKS 
Material specificationFluoropolymer elastomer, Peroxide cured F-type gum polymers, Steam resistant Viton A 
StandardsASME BPE, RoHS 

Technical Summary table lists features available within the range. See ‘Specifications’ tab for model specific information.

Performance

Performance

Flow Coefficient (under standard configuration)
Tank Valve Size CV KV
0.5" 4.3 5.0
1.0" 15.8 18.3
2.0" 72.0 83.2
3.0" 170.0 196.5

Performance

Flow Coefficient (under standard configuration)
Tank Valve Size CV KV
0.5" 4.3 5.0
1.0" 15.8 18.3
2.0" 72.0 83.2
3.0" 170.0 196.5

Performance

Flow Coefficient (under standard configuration)
Tank Valve Size CV KV
0.5" 4.3 5.0
1.0" 15.8 18.3
1.5" 48.0 55.5
2.0" 72.0 83.2
3.0" 170.0 196.5

Specifications

Technical specifications

Viton A diaphragmsViton A (SR) diaphragmsViton GF diaphragms
Tank valve sizes0.5", 0.5" Extended, 1.0", 2.0" 0.5", 1.0", 2.0", 3.0" 0.5" Extended, 1.0", 1.5" Extended, 2.0", 3.0", 3.0" Extended 
ColourCream Black Black 
Diaphragm variant(s)Bellows, Straight Bellows, Straight Straight 
Parylene treatmentNo No No 
Operating temperature range -20 °C to 177 °C-20 °C to 177 °C-20 °C to 177 °C
Operating temperature range -4 °F to 350 °F-4 °F to 350 °F-4 °F to 350 °F
Compatible actuatorsAJS, AKS AJS, AKS AJS, AKS 
Actuator typeManual, Pneumatic Manual, Pneumatic Manual, Pneumatic 
Curing agentBPA BPA Peroxide 
Steaming required prior to installationNo No No 
ASME BPE appendix K SIP cycle rating200 200 200 
Total actuations during SIP cycle testing2000 2000 2000 
Shelf life4 years4 years4 years
Material specificationFluoropolymer elastomer Steam resistant Viton A Peroxide cured F-type gum polymers 
StandardsASME BPE, RoHS ASME BPE, RoHS ASME BPE, RoHS 
CertificationADCF, BSE/TSE free, FDA 21CFR177.2600, USP <87>, USP <88> Class VI ADCF, BSE/TSE free, FDA 21CFR177.2600, USP <87>, USP <88> Class VI ADCF, BSE/TSE free, FDA 21CFR177.2600, USP <87>, USP <88> Class VI 

Materials of construction

DiaphragmSynthetic rubber compound, Viton® A Cream Fluoropolymer Elastimer, Viton® A Steam Grade 42563, Viton® GF 17340
Inserts304 SS

Literature

Brochures

  1. ASEPCO weirless radial diaphragm valves (EN).pdf
    PDF - 600.3kb

Datasheet

  1. ASEPCO diaphragms datasheet (EN).pdf
    PDF - 234.5kb

Order Information

Product codes

Code Product

VG05

Radial diaphragm extended .5" Viton A Cream

VT05

Radial diaphragm .5" Viton A Cream Straight

VT10

Radial diaphragm 1" Viton A Cream Bellows

VT20

Radial diaphragm 2" Viton A Cream Bellows

Code Product

VA05

Radial diaphragm .5" Viton "A" - steam grade Black Straight

VA10

Radial diaphragm 1" Viton "A" - steam grade Black Straight

VA20

Radial diaphragm 2" Viton "A" - steam grade Black USP Straight

VA30

Radial diaphragm 3" Viton "A" - steam grade Black Straight

Code Product

VF10

Radial diaphragm 1" Viton "GF" Black Straight

VF20

Radial diaphragm 2" Viton "GF" Black Straight

VF30

Radial diaphragm 3" Viton "GF" Black Straight

VFE17

Radial diaphragm extended 1.5" Viton "GF" Black

VFE30

Radial diaphragm extended 3" Viton "GF" Black

VGF05

Radial diaphragm extended .5" Viton "GF" Black

Recommended Products

  1. Tank-bottom valves

    Tank-bottom valves

    The leading aseptic tank-bottom valve. Available in multiple configurations including custom-machined.

    Valves - tank valves

  2. Inline valves

    Inline valves

    Our best-selling in-line valve featuring a 180 degree install angle with superior drainability in multiple orientations.

    Valves - inline valves

  3. Sample valves

    Sample valves

    Consistent sampling every time. Behind-the-seat-flow path allows for easy clean-in-place/steam-in-place between samples.

    Valves - sampling

  4. Divert valves

    Divert valves

    Designed to allow division and blending of two or three fluid paths in a single assembly. Eliminates dead legs.

    Valves - tank valves

  5. Insulate valves

    Insulate valves

    Use with freeze tanks or tanks requiring critical temperature control. Extended body and diaphragm.

    Valves - tank valves

  6. Point-of-use valves

    Point-of-use valves

    Created for low-point draining or sampling in piping systems, this valve eliminates dead legs and helps promote drainage.

    Valves - tank valves

  7. Process valves

    Process valves

    A valve with a simple clamp connection for easy installation. Allows steam-in-place or flush through, without dead legs.

    Valves - tank valves

  8. Retrofit valves

    Retrofit valves

    Used to add ASEPCO valves to existing tanks. Many different designs to fit your specific situation.

    Valves - tank valves

  9. Sterillite valves

    Sterillite valves

    An integrated steam valve added to our tank-bottom valve. Allows steam-in-place or flush through, without dead legs.

    Valves - tank valves

  10. Tangential valves

    Tangential valves

    Off-centre outlet for full drainability when installed on the slope of a vessel head.

    Valves - tank valves

  11. Sterile access valves

    Sterile access valves

    Minimise hold-up volume, with two flow paths in one efficient valve.

    Valves - inline valves

  12. I-Sample valves

    I-Sample valves

    Designed with through-the-chamber CIP/SIP via 1/4- to 1/2-inch ports, ensuring a truly representative sample every time.

    Valves - sampling

Related Products

  1. EPDM diaphragms

    EPDM diaphragms

    EPDM diaphragms. Not suitable for use with solvents or petroleum agents.

    Valves - diaphragms

  2. PTFE diaphragms

    PTFE diaphragms

    Long-lasting, quick-change diaphragms. Extremely chemical and steam resistant. Only available for tank valves.

    Valves - diaphragms

Our specialists are here to help you succeed.

To order a product or ask a question